Comparison of spectrophotometric, potentiometric and voltammetric methodologies for the determination of nitrite and nitrate in industrial effluents and in watercourses

Authors

  • Cherrine Kelce Pires Federal University of Rio de Janeiro, Campus Macaé, Rio de Janeiro, Brazil
  • Efraim Lázaro Reis Federal University of Viçosa, Viçosa, Minas Gerais, Brazil
  • Maria Isabel Cristina Batista Mayrink Dynamic Faculty of Vale do Piranga, Ponte Nova, Minas Gerais, Brazil
  • Gabriel Henrique Sperandio Federal University of Viçosa, Viçosa, Minas Gerais, Brazil

DOI:

https://doi.org/10.18540/jcecvl10iss7pp20766

Keywords:

Nitrite, Nitrate, Industrial effluents, Watercourses, Spectrophotometry, Potentiometry, voltammetry

Abstract

The study addresses the importance of treating wastewater, such as water from human activities (domestic, industrial, agricultural), before it is discharged into the environment. The presence of nitrate and nitrite ions in these waters is a concern, as they are harmful to human health. The objective of this study is to evaluate different analytical techniques to measure the amount of these ions in industrial effluents and river water. The water samples were collected in Timóteo, a region with steel industries. The collections were made at three treatment points of a steel industry and at different points of the Timotinho Stream. These samples were filtered and analyzed in the laboratory using three different techniques, UV-Vis Spectrophotometry, Potentiometry with ion-selective electrodes and Differential Pulse Voltammetry. The results showed that all three techniques analyzed were effective in determining nitrite and nitrate in the water samples. However, there were some important considerations: UV-Vis spectrophotometry is quite accurate, but can be affected by interferences in the sample, such as the presence of other substances that absorb light at the same wavelength; potentiometry with ion-selective electrodes, despite being a simpler and lower-cost technique, also presented good results. Because it is more affordable, it is considered an excellent option for use in routine analyses, especially in places where resources are limited; and finally, differential pulse voltammetry, which is a more complex technique, but offers high sensitivity and can be useful in cases where very low concentrations of ions need to be detected. It is concluded that all three techniques can be used to measure nitrate and nitrite in industrial effluents and river waters, with variations in choice depending on the context. This is the main idea of ??the study: to identify effective techniques for measuring hazardous contaminants (such as nitrate and nitrite) in wastewater, choosing the most appropriate technique based on accuracy, sensitivity, and cost.

Downloads

Download data is not yet available.

References

Agudo, E. G. (1987) Guia de coleta e preservação de amostras de água. São Paulo: CETESB. 150p.

Annino, R.; Mcdonald, J. E. (1961) Polarographic determination of nitrite and nitrate. Anal. Chem., 33(3), 475.

Batalha, B. L.; Parlatore, A. C. (1977) Controle da qualidade da água para consumo humano; bases conceituais e operacionais. São Paulo: CETESB. 198p.

Bruning-Fann, C. S.; Kaneene, J. B. (1993) The effects of nitrate, nitrite, and n-nitroso compounds on human health: a review. Vet. Hum. Toxicol. 35(3), 270-272.

COPAM. (1987) Deliberação Normativa n? 10, de 16 de dezembro de 1986. Estabelece normas e padrões para qualidade das águas, lançamento de efluentes nas coleções de águas, e dá outras providências. MG.

Cunniff, P. A. (1998) Official methods of analysis of AOAC International. Arlington: AOAC International, 16.ed. 2100p.

EG?G PARC. Model 384B (1988) Polarographic analyser instruction manual. ?S.l.?: Princeton Applied Research Corporation.

Greenberg, A. E.; Clesceri, L. S.; Eaton, A. D. (Eds.) (1992) Standard methods for the examination of water and wastewater. 18.ed. Washington: American Public Health Association. 1, Irregular pagination.

Microcal Origin. Data analysis and technical graphics software. Origin Professional Version 9.0.0 SR2. Northampton, MA, 2013. 774 p.

Morita, T.; Assumpção, R. M. V. (1983) Manual de soluções, reagentes e solventes. 2. ed. São Paulo: Edgard Blucher. 627p.

Orion. (1996a) Nitrate electrode instruction manual. Beverly: Orion Research. 67p.

Orion. (1996b) Nitrite electrode instruction manual. Beverly: Orion Research. 69p.

Pizeta, I.; Branica, M. (1988) Computer automation of polarographic analyzer PAR-384B and development of specific implementation software. J. Electroanal. Chem. 250(2), 293-299. doi: https://doi.org/10.1016/0022-0728(88)85171-4

Reis, E. L; Gonzaga, F. B.; Reis, C.; Mayrink, M. I. C. B.; Custódio, G. (2021) Desenvolvimento de software em visual basic para gerenciamento e aquisição de dados do polarógrafo PAR 384B. Revista Científica Multidisciplinar Núcleo do Conhecimento. 144-160.

doi:https://doi.org/10.32749/nucleodoconhecimento.com.br/tecnologia/software-em-visualbasic

Singh, P.; Singh, M. K.; Beg, Y. R.; Nishad, G. R. (2019). A review on spectroscopic methods for determination of nitrite and nitrate in environmental samples. Talanta. 191, 364-381. doi: https://doi.org/10.1016/j.talanta.2018.08.028

Wang, Q.; Yu, L.; Liu, Y.; Lin, L.; Lu, R.; Zu, J.; He, L.; Lu, Z. (2017). Methods for the detection and determination of nitrite and nitrate: A review. Talanta. 165, 709-720. https;//doi.org/10.1016/j.talanta.2016.12.044

Wierzbicka, E. (2019). Novel methods of nitrate and nitrite determination – A review. J. Elem. 25(1), 97-106. https://doi.org/10.5601/jelem.2019.24.3.1848.

Downloads

Published

2024-12-04

How to Cite

Pires, C. K., Reis, E. L., Mayrink, M. I. C. B., & Sperandio, G. H. (2024). Comparison of spectrophotometric, potentiometric and voltammetric methodologies for the determination of nitrite and nitrate in industrial effluents and in watercourses. The Journal of Engineering and Exact Sciences, 10(7), 20766. https://doi.org/10.18540/jcecvl10iss7pp20766

Issue

Section

General Articles