GATE code in the image generation and dose calculation of a conventional tomographic system

Authors

  • Felix Mas Milian Departamento de Engenharias e Computação, Universidade Estadual de Santa Cruz, Brasil Centro de Pesquisa e Desenvolvimento Tecnológico em Informática e Eletroeletrônica de Ilhéus, Brasil
  • Paulo Eduardo Ambrosio Departamento de Engenharias e Computação, Universidade Estadual de Santa Cruz, Brasil Centro de Pesquisa e Desenvolvimento Tecnológico em Informática e Eletroeletrônica de Ilhéus, Brasil https://orcid.org/0000-0002-6043-3591
  • Susana Marrero Iglesias Departamento de Engenharias e Computação, Universidade Estadual de Santa Cruz, Brasil Centro de Pesquisa e Desenvolvimento Tecnológico em Informática e Eletroeletrônica de Ilhéus, Brasil https://orcid.org/0000-0002-4955-6216
  • Marcelo Ossamu Honda Departamento de Engenharias e Computação, Universidade Estadual de Santa Cruz, Brasil Centro de Pesquisa e Desenvolvimento Tecnológico em Informática e Eletroeletrônica de Ilhéus, Brasil https://orcid.org/0000-0001-9008-2211
  • Allan Medeiros Martins Centro de Pesquisa e Desenvolvimento Tecnológico em Informática e Eletroeletrônica de Ilhéus, Brasil
  • Dany Sanchez Dominguez Departamento de Engenharias e Computação, Universidade Estadual de Santa Cruz, Brasil Centro de Pesquisa e Desenvolvimento Tecnológico em Informática e Eletroeletrônica de Ilhéus, Brasil https://orcid.org/0000-0002-0640-2970

DOI:

https://doi.org/10.18540/jcecvl10iss01pp17803

Keywords:

Tomography, Monte Carlo Simulation, Dosimetry, GATE Code

Abstract

This work presents a methodology to perform simulations of cone beam tomography using the GATE code. Two computational models, ICRP110 and MASH3, were used for patient representation. For each model, 360 images were obtained representing the attenuation pattern of a 120kV photon beam when passing through the patient in a complete rotation. 3D CT images were reconstructed using a commercial program to evaluate the simulation approach, obtaining very satisfactory results. Moreover, our group found promising results using a reconstruction code under development. In addition, the deposited dose was obtained for each beam direction and the entire CT exam. The presented methodology can be used in further works to design and optimize new types of CT scanners.

Downloads

Download data is not yet available.

Published

2024-01-03

How to Cite

Milian, F. M., Ambrosio, P. E., Iglesias, S. M., Honda, M. O., Martins, A. M., & Dominguez, D. S. (2024). GATE code in the image generation and dose calculation of a conventional tomographic system. The Journal of Engineering and Exact Sciences, 10(1), 17803. https://doi.org/10.18540/jcecvl10iss01pp17803